     Featuring the CEH  Order Form

Industrial Unit Heater

CEH003-P Model 3,300/2,500 WATTS -   Shipped Price of $379.00

CEH003-P Model 5,000/3,7500 WATTS -   Shipped Price of $439.00

  
 Grill or Product Dimensions:
16"H x 14"W x 8.25"D
 
   Appreciate air throw is 12'.
 

General Information:
Calculate the heat loss of the area to be heated. It is recommended that one of the following methods be used: ASHRAE Guide and Data Book (The American Society of Heating, Refrigeration & Air Conditioning Engineers); The NEMA Handbook (The National Electrical Manufacturer's Association); or the ACCA Manual J (The Air Conditioning Contractors of America). The layout of the space to be heated must be taken into consideration to determine the selection of the best size and air displacement. Most applications benefit from a combination of vertically and horizontally discharged air delivery. In buildings with large doors that are frequently opened, use a high velocity heater with horizontal air flow across the opening, or use an infrared heater. In smaller areas where comfort is a prime consideration, more heaters of smaller capacity are recommended. Smaller KW heaters are also recommended for low mounting heights to avoid discomfort and increased noise levels. Additionally, there is better air distribution by using a greater number of lower KW heaters.

Horizontal Air Flow – Position heaters to allow the air flow to "wipe" the exposed walls without blowing directly against the wall. Spacing between the heaters should be approximately 1.5 times the "air throw" of the heaters (Approx air throw 12') .

Vertical Air Flow – When vertical discharging heaters are used exclusively, the air streams must overlap to blanket outside walls to provide good heat distribution. Vertical air flow is best used for areas with high ceilings or bays. Vertical discharging units are to be mounted high above machinery, assembly lines, etc. Vertical discharging units are best used when the perimeter heat loss is adequately controlled.
 

Architectural Information:
Fan forced unit heater shall be UL Listed and rated at 208, 240, 277 or 480 Volt. Horizontal or vertical mounting shall be possible to direct discharged air. External cabinet shall be constructed of 20 gauge high quality steel. All metal surfaces of the cabinet, external and internal, shall be finished with a baked on powder coat paint system. Fan shall be aluminum blade axial flow type, and mounted directly to the motor shaft. Motor shall be shaded pole, industrial rated, with an inherent overheating protection device. Heating elements shall be sealed in magnesium powder and protected by metal sheathing, over which aluminum fins are applied. Heater shall be equipped with manual reset thermal cut out for over temperature protection. Fan motor circuit shall be thermostatically controlled, allowing fan to remain operating after the elements have shut off, discharging the residual element heat. Wiring compartment shall have convenient access door with captured hardware.
 

Features and Benefits
Manual reset thermal protection
Commercial grade high temperature manual reset with 25 amp rating at 240 Volt
High mass, tubular element for longer life
Fan delay eliminates cold draft on startup and disperses residual heat on shutdown
Rugged die formed construction for durability
Wire single or three phase to suit the application
Mounts vertically or horizontally
5 Year Warranty
Almond Color

Model#

Description

Watts
240V

Amps  240V

 CFM

FPM TEMP.RISE MOTOR HP MOTOR RPM   SHIPPED PRICE ORDER!

CEH003-P

Unit Heater

3,300/2,500 13.80/12.00 350 940 30 1/70 1600 $379.00 Order!  

CEH005-P

Unit Heater

5,000/3,750 20.80/18.00 350 940 45 1/70 1600 $439.00  Order!  

CEKV1

Air Vane Louver Kit (Optional Accessories)

               $61.00 Order!  

CEKTB1

Single Pole Field Mount Stat (Optional Accessories)

               $93.00 Order!  

CEKTB2

2 Stage Field Mount Stat (Optional Accessories)

               $125.00 Order!  

CEKM1

Ceiling Hat Bracket (Optional Accessories)

               $58.00 Order!  

CEKWM

Wall Hanger Arm (Use w/CEK-M1) (Optional Accessories)

               $68.00 Order!  